================================================================================ Release Notes ================================================================================ This document describes the features, known issues, and resolutions in OpenManage Integration for Microsoft System Center (OMIMSSC) Version 7.1.1 for System Center Operation Manager (SCOM). The Dell EMC Server Management Pack Suite for System Center Operations Manager 2019, System Center Operations Manager 1807, System Center Operations Manager 1801, Microsoft System Center 2016 Operations Manager, System Center Operations Manager 2012 R2 enables the monitoring of Dell EMC Servers, Integrated Dell EMC Remote Access Controllers (iDRAC) and Dell EMC Chassis Management Controller (CMC)/OpenManage Enterprise – Modular(OME-M). The management packs provide Dell EMC-specific views that you can use to observe and drill down the system status in a network. -------------------------------------------------------------------------------- Version: 7.1.1 -------------------------------------------------------------------------------- Release Date: June 2019 -------------------------------------------------------------------------------- Previous Version: 7.1 -------------------------------------------------------------------------------- Importance Recommended: Dell EMC recommends the customer review specifics about the update to determine if it applies to your system. The update contains changes that impact only certain configurations, or provides new features that may/may not apply to your environment. Note: This Patch is only applicable to OpenManage Integration for Microsoft System Center Version (OMIMSSC) 7.1 for System Center Operation Manager (SCOM). Not applicable for Microsoft System Center Configuration Manager (SCCM) and System Center Virtual Machine Manager (SCVMM) platforms. ================================================================================ What is supported? ================================================================================ ------------------------------------------- Dell EMC Server and Rack Workstation Monitoring ------------------------------------------- Management Server (MS) requirements: ------------------------------------ Supported operating systems: ---------------------------- * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 ----------------------------------------------------------------- Managed System requirements: ---------------------------- Supported versions: ----------------------------------------------------|-------------------| Dell EMC OpenManage Server Administrator (OMSA) | Version | ----------------------------------------------------|-------------------| Dell EMC OpenManage Server Administrator (OMSA) 14G | v9.2 and v9.0.1 | ----------------------------------------------------|-------------------| Dell EMC OpenManage Server Administrator (OMSA) 13G | v9.2 and v9.1 | ----------------------------------------------------|-------------------| ------------------------------------------------------ Dell EMC Server and Rack Workstation Monitoring (Licensed) ------------------------------------------------------ Management Server (MS) requirements: ------------------------------------- Supported operating systems: ---------------------------- * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 ----------------------------------------------------------------- Managed System requirements: ---------------------------- Supported firmware versions: ----------------------------------|-----------------------| iDRAC | Firmware versions | ----------------------------------|-----------------------| 12th generation of PowerEdge | 1.6x.6x and 2.xx.xx.xx| Servers with iDRAC7 | | ----------------------------------|-----------------------| 13th generation of PowerEdge | 2.xx.xx.xx | Servers with iDRAC8 with | | Lifecycle Controller | | ----------------------------------|-----------------------| 14th generation of PowerEdge | 3.xx.xx.xx | Servers with iDRAC9 with | | Lifecycle Controller | | ----------------------------------|-----------------------| ------------------------------------------------------ iDRAC Service Module (iSM) Monitoring Feature ------------------------------------------------------ Management Server (MS) requirements: ------------------------------------- Supported operating systems: ---------------------------- * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 ----------------------------------------------------------------- Managed System requirements: ---------------------------- Supported firmware versions: ---------------------------------|----------------| iDRAC Service Module (iSM) | Version | ---------------------------------|----------------| iDRAC Service Module (iSM) 14G | v3.3 and v3.2 | ---------------------------------|----------------| iDRAC Service Module (iSM) 13G | v2.5 and v2.4 | ---------------------------------|----------------| ------------------------------------ Dell EMC Chassis Monitoring Feature ------------------------------------ Management Server (MS) requirements: ------------------------------------ Supported operating systems: ---------------------------- * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 ----------------------------- Managed System requirements --------------------------- Supported firmware versions: ---------------------------|--------------------| Chassis | Firmware versions | ---------------------------|--------------------| Dell EMC PowerEdge FX2/FX2s| 2.20 and 1.41 | ---------------------------|--------------------| Dell EMC PowerEdge VRTX | 3.2 and 2.22 | ---------------------------|--------------------| Dell EMC PowerEdge M1000e | 6.20 and 5.21 | ---------------------------|--------------------| ------------------------------------ OpenManage Enterprise – Modular Monitoring Feature ------------------------------------ Management Server (MS) requirements: ------------------------------------ Supported operating systems: ---------------------------- The Chassis Detailed edition is supported only on OpsMgr 2016 and OpsMgr 2012. * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 ----------------------------- Managed System requirements --------------------------- Supported firmware versions: ----------------------------------|--------------------| OpenManage Enterprise – Modular | Firmware versions | ----------------------------------|--------------------| Dell EMC PowerEdge MX7000 | 1.0 | ----------------------------------|--------------------| ------------------------------------- iDRAC Monitoring Feature ------------------------------------- Management Server (MS) requirements: ------------------------------------- Supported operating systems: --------------------------- * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 --------------------------- Managed System requirements --------------------------- Supported firmware versions: ----------------------------------------------------------|--------------------------------------| iDRAC | Firmware versions | ----------------------------------------------------------|--------------------------------------| iDRAC6 Modular | 3.80 and 3.65 | ----------------------------------------------------------|--------------------------------------| iDRAC6 Monolithic | 2.92 and 2.85 | ----------------------------------------------------------|--------------------------------------| iDRAC7 Modular and Monolithic | 2.xx.xx.xx and 1.6x.6x | ----------------------------------------------------------|--------------------------------------| iDRAC8 with Lifecycle Controller Modular and Monolithic | 2.xx.xx.xx | ----------------------------------------------------------|--------------------------------------| ------------------------------------- Dell EMC Network Switch Monitoring Feature ------------------------------------- Management Server (MS) requirements: ------------------------------------- Supported operating systems: --------------------------- * For OpsMgr 2019, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-2019. * For Operations Manager 1807, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1807. * For OpsMgr 1801, see docs.microsoft.com/en-us/system-center/scom/?view=sc-om-1801. * For OpsMgr 2016, see technet.microsoft.com/en-us/library/dn997272(v=sc.16).aspx system-requirements * For OpsMgr 2012 R2, see technet.microsoft.com/en-us/library/hh205990 --------------------------- Managed System requirements --------------------------- Supported firmware versions: --------------------------------|-----------------------| Network Switch Series | Firmware versions | --------------------------------|-----------------------| S Series | 6.5.xx | --------------------------------|-----------------------| M Series | 9.13.xx | --------------------------------|-----------------------| N Series | 9.13.xx | --------------------------------|-----------------------| Z Series | 9.13.xx | --------------------------------|-----------------------| ----------------------------------------------- Chassis Modular Server Correlation Feature ----------------------------------------------- The Chassis Modular Server Correlation Feature is used for correlation of Chassis slots with its Modular blades. Modular blades could be discovered either through Server and Rack Workstation Monitoring feature or Server and Rack Workstation Monitoring (Licensed) feature. * For supported Dell EMC Chassis versions, please see the 'Supported firmware versions' section under Chassis Monitoring Feature. * For supported iDRAC version, please see the 'Supported firmware versions' section under Server and Rack Workstation Monitoring (Licensed) feature. * For supported iSM versions, please see the'Supported versions' section under Server and Rack Workstation Monitoring feature. * For supported OMSA versions, please see the'Supported versions' section under Server and Rack Workstation Monitoring feature. ================================================================================ What’s New ================================================================================ • Support for System Center Operations Manager 1801, System Center Operations Manager 1807 and System Center Operations Manager 2019. • Fixes for the security enhancement for read-only users not to get elevated permissions. ================================================================================ Fixes ================================================================================ • With this release, OMIMSSC infrastructure has been enhanced to block read-only users to get any elevated permissions. ================================================================================ Important Notes ================================================================================ Management Pack Suite Structure -------------------------------- The Dell EMC Server Management Pack Suite consists of the following management packs, which are extracted into the installation folder. | Dell.FeatureManagement.Pack.mp | * Dell EMC Feature Management Pack (FMP) provides a dashboard to monitor | supported Dell EMC Management Pack Suite features, import | (scalable/detailed), upgrade, and remove management features. | For more information, see the the Dell EMC Server Management Pack Suite | Version 7.1.1 for Microsoft System Center Operations Manager Installation | Guide. | +---Dell EMC Server Monitoring | | Dell.WindowsServer.Scalable.mp | * Dell EMC Windows Server (Scalable Edition) Management Pack for discovery | and monitoring of Dell EMC Servers through the Server and Rack Workstation | Monitoring feature. | Dell.WindowsServer.Detailed.mp | * Dell EMC Windows Server (Detailed Edition) Management Pack for detailed | discovery and monitoring of Dell EMC Servers and its components through the | Server and Rack Workstation Monitoring feature. | Dell.WindowsServer.InformationAlertsOn.mp | * Dell EMC Overrides utility for turning ON the Informational Alerts | provided in the Dell EMC Windows Server (Scalable Edition) Management Pack. | Dell.Server.SDK.mp | * Dell EMC Server Model Management Pack for discovery and monitoring of Dell | EMC Server and its components of 12th 13th and 14th generation of PowerEdge | Servers on OpsMgr 2016, OpsMgr 2012 R2. | Dell.View.SDKServer.mp | * Dell EMC Server View Management Pack has view type definitions for the Dell | EMC Agent-free Server Management Pack and Dell EMC Agent-based Server | Management Pack. | Dell.Model.Server.mp | * Dell EMC Server Model Library file for Server monitoring | Dell.OperationsLibrary.Server.mp | * Dell EMC Server Operations Library file for Server monitoring | Dell.View.Server.mp | * Dell EMC Server View Library file for Server monitoring | Dell.ManagedServer.Model.mp | * Dell EMC Managed Server Model Library file for Server monitoring using iSM | Dell.ManagedServer.iSM.mp | * Dell EMC Managed Server iSM Management Pack enables discovery with scalable | inventory and monitoring of 12th, 13th and 14th generation of PowerEdge | Servers on OpsMgr 2016 and OpsMgr 2012 R2. | Dell.ManagedServer.iSM.Detailed.mp | * Dell EMC Managed Server iSM Management Pack (Detailed Edition) enables | detailed inventory and monitoring of 12th, 13th and 14th generation of | PowerEdge Servers on OpsMgr 2016 and OpsMgr 2012 R2. | Dell.Group.Creation.DellProxy.mp | * Dell EMC Group Creation Management pack is to create Proxy VM group in SCOM | Management Server. | Dell.Server.OpenManage.Dashboard.View.mp | * Dell EMC OpenManage Integration Dashboard View Management pack contains the | Dell EMC OpenManage Integration Console Dashboard View where Server, Chassis, | Switch discovery and discovery, health and metrics time interval can be | override. Sync Operation can be performed | Dell.Appliance.Information.mp | * Dell EMC Appliance Information Management Pack to facilitate keeping Dell EMC | Appliance Information. | Dell.SDK.ApplianceIP.Override | * Dell EMC SDK Appliance IP Override Management Pack to facilitate Dell EMC | Appliance IP Information | +---Dell EMC Chassis Monitoring | | Dell.CMC.OM07.mp | * Dell EMC Chassis Management Controller (CMC) Management Pack for discovery, | monitoring, and trap processing of Dell EMC Chassis with OpsMgr 2007 R2. | Dell.CMC.OM12.mp | * Dell EMC Chassis Management Controller Management Pack for discovery, | monitoring, and trap processing of Dell Chassis with OpsMgr 2016, | OpsMgr 2012 versions. This is the scalable edition. | Dell.Chassis.Detailed | * Detailed edition of the Dell EMC Chassis Management Controller | Management Pack with OpsMgr 2016, OpsMgr 2012 versions. This | management pack supports detailed discovery and monitoring of Dell | EMC Chassis and its components. | Dell.Model.CMC.mp | * Dell EMC CMC Model Library file for Dell EMC Chassis monitoring | Dell.OperationsLibrary.CMC.mp | * Dell EMC CMC Operations Library file for Dell EMC Chassis monitoring | Dell.View.CMC.mp | * Dell EMC CMC View Library file for Dell EMC Chassis monitoring | Dell.CMC.SDK.mp | * Dell EMC Chassis CMC Model Management pack contains the Classes, Discovery and | UnitMonitor for the Dell EMC Chassis and its components. | Dell.View.SDKCMC.mp | * Dell EMC Chassis CMC View Management pack defines the views used by the Dell | EMC Chassis Management Controller (CMC) Management Pack. | +---Dell EMC NetworkSwitch Monitoring | | Dell.NetworkSwitch.mp | * Dell EMC NetworkSwitch Management Pack contains the discovery and UnitMonitor | for the Dell EMC NetworkSwitch and its components. | Dell.View.NetworkSwitch.mp | * Dell EMC NetworkSwitch View Management Pack defines the views used by the Dell | EMC NetworkSwitch Management Pack. | +---Dell EMC Remote Access Monitoring | | Dell.DRAC.OM07.mp | * Dell EMC Remote Access Controller(DRAC) Management Pack for discovery, | monitoring and trap processing of DRAC devices with OpsMgr 2007 R2. | Dell.DRAC.OM12.mp | * Dell EMC Remote Access Controller(DRAC) Management Pack for discovery, | monitoring and trap processing of DRAC devices with OpsMgr 2016, | OpsMgr 2012 versions. | Dell.Model.DRAC.mp | * Dell EMC DRAC Model Library file for DRAC monitoring | Dell.OperationsLibrary.DRAC.mp | * Dell EMC DRAC Operations Library file for DRAC monitoring | Dell.View.DRAC.mp | * Dell EMC DRAC View Library file for DRAC monitoring | +---Dell EMC Chassis Modular Server Correlation | | Dell.ChassisModularServer.Correlation.mp | * Dell EMC Chassis Blade Correlation utility for turning ON the | correlation of chassis with discovered modular server blades. | This MP requires Dell.Server.SDK, Dell.CMC.SDK, Dell.ManagedServer.iSM, | Dell.ManagedServer.Model and Dell.WindowsServer.Scalable MPs. | * This management pack supports the correlation of Dell EMC Chassis | storage assigned to modular server blades. | +---Dell EMC Library | | Dell.Connections.HardwareLibrary.mp | * Dell EMC Base folder utility for basic folder structure and Root node. | Dell.OperationsLibrary.Common.mp | * Library file used by Dell EMC Management Pack Suite components. | Dell EMC Server and Rack Workstation Monitoring: -------------------------------------------- * The Attribute "Enable Correlation" for "Dell EMC Windows Server Physical and Teamed Relationship Discovery Rule" is set to "False" for all Teamed Network Interface (Enriched) in the Dell EMC Windows Server (Detailed Edition) Management Pack. Set the attribute value to "True", to see the relationships between Physical and Teamed Network Interfaces in the "Complete Diagram View", "Modular Systems Diagram View" and "Monolithic Servers Diagram View" * The Performance Rules "Total Transmitted Packets", "Received Bytes", "Total Received Packets" and "Transmitted Bytes" are disabled by default for all Physical/Teamed Network Interface (Enriched) in the Dell EMC Windows Server (Detailed Edition) Management Pack. Enable these rules to generate performance statistics for the Physical/Teamed Network Interfaces. * The Dependency Monitor "Dell EMC Server Availability Rollup (from iDRAC)" is disabled by default for all Dell EMC Servers in the Dell EMC Scalable management pack. Enable this monitor to roll up the iDRAC network interface health to the Dell EMC Server health. * The Performance Rule "Dell EMC Server (Agent-based) Physical Disk (SSD) Performance", is disabled by default for all Physical Disks and is a part of the Dell Windows Server (Detailed Edition) Management Pack. Enable this rule to generate performance statistics for the Remaining Rated Endurance Level of the SSDs (Solid State Drives). * Physical disks connections are not displayed accurately when the disks are connected to different connectors. All connected disks are displayed under a single connector. Dell EMC Server and Rack Workstation Monitoring (Licensed): ------------------------------------------------------- * To use the Licensed Server features, download the Microsoft WS-Management template from the Microsoft download location as mentioned in the Dell EMC Server Management Pack Suite Version 7.1.1 for Microsoft System Center Operations Manager User’s Guide. * Performance Unit Monitors are disabled by default. Enable the performance unit monitors to get performance health status. * Health Monitoring for components under Software RAID controllers is not supported. Data required for health monitoring not available from the device for such components. * Network Link status for PowerEdge FX2/FX2s chassis shows internal NIC connectivity; network cable removal does not affect Network Link status for PowerEdge FX2/FX2s chassis. * Correlation of the shared storage between PowerEdge VRTX chassis and the server is not available for Dell EMC servers discovered through Dell EMC Server and Rack Workstation Monitoring (Licensed) feature; it is supported only for servers discovered through the Server and Rack Workstation Monitoring feature. * Physical disks connections are not displayed accurately when the disks are connected to different connectors. All connected disks are displayed under a single connector. * Event Auto-Resolution feature is supported only for servers discovered through WSMAN. This feature is disabled by default. Enable the feature through Feature Management Dashboard. * Discovery of the devices should be done in batches, maximum of 250 server batch at a time. * For the devices discovered through the appliance console, after the first time discovery component health will be updated after 1 hour. * When the number of licensed nodes in detailed mode of discovery exceeds the threshold limit then the monitoring mode using licensed feature will be automatically switched to scalable mode. * In SCOM when a Proxy-MS is added or removed as a resource from the Dell Proxy MS Group, then clicking “Sync with MSSC” in the OMIMSSC dashboard is mandatory for proper workflow distribution in all the Proxy MS resources. * In case of upgrade situation from previous version of DSMPS (7.0 or below) to Version 7.1 and later: User will install newer version of Dell EMC MPs by enrolling SCOM to appliance, after this user will discover same devices by synchronizing devices from SCOM to OMIMSSC or by directly OMIMSSC dashboard, for older discovered devices empty discovery data will be submitted which will clear previously discovered device objects.  Note: Older versions of MPs should be deleted only after 30 days of new discovery. Dell EMC Chassis Monitoring: ------------------- * In Slot Discovery, the slot name for the slots containing FD332 Storage block, will be shown as SLOT-(Slot Number). * Slot names displayed by Dell EMC Chassis Slot Discovery may differ from the slot names shown by the Dell Chassis web console. * To monitor the alerts of Chassis devices, associate the community string Run As account with the SNMP Monitoring Account with the target as Dell EMC Modular Chassis class or respective Chassis object (if you have different Run As accounts for different Chassis devices.) * Health Monitoring of PCIe devices are not supported in the Chassis Detailed Monitoring feature. * Chassis Power Consumption performance metrics is supported in the Dell EMC chassis (Detailed Edition) Management Pack. Enable Metrics in OpenManage Dashboard to generate performance statistics for Chassis Aggregate Power consumption. * In case of upgrade situation from previous version of DSMPS (7.0 or below) to Version 7.1 and later: User will install newer version of Dell EMC MPs by enrolling SCOM to appliance, after this user will discover same devices by synchronizing devices from SCOM to OMIMSSC or by directly OMIMSSC dashboard, for older discovered devices empty discovery data will be submitted which will clear previously discovered device objects.  Note: Older versions of MPs should be deleted only after 30 days of new discovery. ================================================================================ Known Issues ================================================================================ * Issue 1 After applying 7.1.1 patch on 7.1 appliance where few devices were discovered with discovery mode set to detailed, import the FMP manually. Then the Discovery mode that was configured in 7.1 appliance does not get updated in FMP dashboard. Resolution For updating the monitoring level, go to the appliance override page, de-select and select the check-box for any monitoring feature, and then refresh FMP dashboard. Versions Affected Dell EMC OpenManage Integration v7.1.1 for Microsoft System Center for Operations Manager 2019, 1807 and 1801. * Issue 2 After you remove the management pack, the management pack folders are still displayed in SCOM console. Resolution Close and re-open the SCOM console. Versions Affected - All * Issue 3 Despite updating the default port number, CMC or DRAC running firmware version 3.0 returns the wrong URL. Resolution None Versions Affected - 7.1 (Chassis Monitoring and DRAC Monitoring Feature) * Issue 4 Servers discovered through the Server and Rack Workstation Monitoring feature are shown with the default logical device icon Resolution None Versions Affected - 7.1 (Server and Rack Workstation Monitoring Feature) * Issue 5 If the component is under a Software RAID controller, Inventory for Bus Type and Media Protocol in Virtual Disk is not supported Resolution Please see the iDRAC documentation for updated support. Versions Affected - All * Issue 6 Inventory field Manufacturer for SATA Disks may be incorrectly reported as "ATA" Resolution None. Versions Affected - 7.1 (Server and Rack Workstation Monitoring Feature (Licensed)) * Issue 7 NIC Inventory field for Virtual MAC Address are displayed as "00:00:00:00:00:00", if Virtual MAC Address has not been configured for the NIC. This issue affects the Server and Rack Workstation Monitoring (Licensed) feature in version 6.3 and the out-ofband or the agent based monitoring feature of versions 6.0 and later. Resolution None Version affected - 7.1 * Issue 8 The Fan components of the PowerEdge M1000e chassis are displayed as ‘Dell Fan’. Resolution Upgrade PowerEdge M1000e firmware to 5.0.1 Versions Affected - All * Issue 9 In Chassis inventory, the IP address may not be updated for the IO module. Resolution None. Versions Affected - All (Chassis Monitoring Feature (Detailed), Firmware 5.0.1) * Issue 10 If Modular servers which are correlated to a Chassis slot are removed from the SCOM monitoring,the main server object may still be shown. Resolution None. Versions Affected - 7.1 (Chassis Modular Server Correlation, Server and Rack Workstation Monitoring, Server and Rack Workstation Monitoring Feature (Licensed)) * Issue 11 When M1000e chassis is discovered with controller inserted in slot2, and slot1 is empty, then the value of the firmware version is displayed as "Not Applicable". Resolution Insert the controller in SLOT1 Version affected - 7.1 (Chassis Monitoring Feature (Detailed) * Issue 12 Deletion of devices from appliance to scom can take a long time depending on the number of devices deleted at a time. Resolution Select small set of devices for deletion at a time. Wait for few minutes after the completion of a deletion task and then proceed to trigger the next deletion. Version affected - 7.1 * Issue 13 If unreachable IPs are given for discovery, then discovery for those devices will run periodically and task created by appliance cannot be deleted for them. Resolution If provided credentials are wrong then use edit credentials profile page to correct them. Version affected - 7.1 * Issue 14 After reboot of appliance, monitoring will not happen until next discovery which was scheduled to be done for that particular device. Thus, health update can take upto 24 hours to occur. Resolution Use Configuration override page to change only discovery override after reboot. This will ensure discovery to happen immediately and then Health Unit Monitors will also be updated in next default cycle. Version affected - 7.1 * Issue 15 If Servers are discovered through sync operation in appliance and if in the next discovery, port or credentials are changed, discovery of such a device in Appliance will fail in the consequent discovery cycles and resolve sync errors page will not show this device. Resolution None Version affected - 7.1 * Issue 16 Names for Groups, object discoveries, KB articles and Feature name column of FMP Dashboard are not changed to Dell EMC. Resolution None Version affected - 7.1 * Issue 17 When FM/FC blades which are present in an FX2/FX2s chassis where the “Chassis Management at Server node” is set to “Manage and monitor” are discovered from the OMIMSSC dashboard, the Power supply and Fan sensor groups are shown as sub components of the server. Post this if the “Chassis Management at Server node” set to “None” or disabled from the iDRAC console of the blade server, then in the consequent discoveries the Power supply group and the Fan sensor will be retained with health state as “Warning” to indicate an unknown health state of the groups. Resolution None Version affected - 7.1 * Issue 18 If after enrollment Dell EMC OpenManage Integration Dashboard in the Operations Manager console is not launching or if after the enrollment there is a change in Appliance IP. Resolution Update the OMIMSSC appliance IP in Dell EMC SDK Override Appliance IP Unit monitor override. Version affected - 7.1 * Issue 19 The appliance device discovery job that is triggered gets stuck in the running task for a long time (more than 5 hrs) in the OMIMSSC Appliance. Resolution Create the discovery task again in Console UI for same set of IP's with different job name. Version affected - 7.1 ================================================================================ Limitations ================================================================================ * Detection of unresponsive CMC feature is not supported for 13G FX2 chassis discovered through iDRAC Service Module (iSM) using Windows Management Instrumentation (WMI). * Setting preferred monitoring feature through Feature Management Dashboard will not apply to Dell EMC Server discovered under Dell EMC Server and Rack Workstations (Licensed) State View via OMIMSSC. ================================================================================ Installation Procedure ================================================================================ * To install the Dell EMC Server Management Pack Suite 7.1, deploy the Dell EMC OMIMSSC 7.1 available as .vhd and enroll the Management Server in Appliance Web Console. For detailed installation, pre-requisites, configuration, upgrade and uninstallation instructions, see the  Dell EMC OpenManage Integration Version 7.1 for Microsoft System Center Operations Manager Installation Guide at Dell.com/openmanagemanuals. * Patch version 7.1.1 can be applied on Dell EMC OMIMSSC 7.1. For detailed installation, pre-requisites, configuration, upgrade and uninstallation instructions, see the Dell EMC OpenManage Integration Version 7.1.1 for Microsoft System Center Operations Manager Installation Guide at Dell.com/openmanagemanuals. ================================================================================ Contacting Dell EMC ================================================================================ Note: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell EMC product catalogue. Dell EMC provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell EMC for sales, technical support, or customer service issues: 1. Visit www.dell.com/support. 2. Select your support category. 3. Verify your country or region in the Choose a Country/Region drop-down menu at the top of page. 4. Select the appropriate service or support link based on your need. For remote enterprise documentation, go to dell.com/esmmanuals. For information on documentation support, visit www.dell.com/support/manuals. On the Manuals page, click Software -> Systems Management. Click on the specific product on the right-side to access the documents. -------------------------------------------------------------------------------- Information in this document is subject to change without notice. Copyright © 2019 Dell EMC Inc, or its subsidiaries. All Rights Reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell EMC and the Dell EMC logo are trademarks of Dell EMC Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.